Learn about our AROMA analyzers

Compliance & Air Toxics Monitoring with AROMA

Compliance & Air Toxics Monitoring with AROMA

Ensuring Compliance with Advanced VOC Monitoring

Regulatory compliance in air quality monitoring is essential for industries emitting hazardous air pollutants (HAPs). Compliance requires high-precision measurement solutions that provide real-time, accurate, and cost effective monitoring of volatile organic compounds (VOCs) and air toxics.

Entanglement Technologies’ AROMA, powered by Thermal Desorption Cavity Ring-Down Spectroscopy (TD-CRDS), delivers sensitive, real-time measurements of key air toxics, enabling industries to streamline compliance, reduce costs, and improve operational efficiency across a range of applications. AROMA is also a critical tool for ensuring environmental sustainability and worker protection across industries.

AROMA for Air Toxics Monitoring

  • Unmatched Sensitivity & Selectivity: Detects critical VOCs such as ethylene oxide (EtO), benzene, and 1,3-butadiene at parts-per-trillion (pptv) detection limits. 
  • Robust & Versatile: Deployable for stationary, mobile, and multipoint monitoring applications. 
  • Streamlined Sampling & Analysis: TD-CRDS eliminates complex calibration routines, providing faster results and reduced operational costs. 
  • Alternative Test Method (ATM) Eligibility: AROMA provides real-time, high-sensitivity VOC monitoring that can be submitted for EPA approval as an Alternative Test Method (ATM) by facilities seeking compliant solutions. 

To learn more about AROMA, visit the Products page.

Compliance Applications & Solutions

2. Indoor Air 3. CEMS 5. Stack & Source Testing

1 Fenceline Monitoring & Mobile Deployments (HON & Rule 1405)

AROMA provides high-sensitivity, real-time VOC monitoring for fenceline applications, including compliance with the EPA’s Hazardous Organic NESHAP (HON rule). Designed for both stationary and mobile deployments, AROMA enables facility-wide emissions tracking and rapid source identification.

Key Features:

  • Mobile and stationary deployment options for flexible monitoring
  • Concentration mapping for detailed spatial analysis
  • Real-time data reporting and analytics for compliance and decision-making
  • Supports regulatory compliance, including HON rule requirements

2 Indoor Air Quality & Worker Safety (FIFRA)

AROMA provides real-time monitoring of VOCs in indoor environments, ensuring worker safety and compliance with occupational exposure limits. Its rapid response and high sensitivity make it ideal for detecting leaks, tracking exposure levels, and optimizing air quality in industrial and commercial settings.

Key Features:

  • Continuous monitoring for worker exposure and indoor air quality
  • Supports industrial hygiene and regulatory compliance
  • Rapid multi-point sampling for facility-wide air quality assessments

3 Continuous Emissions Monitoring (CEMS) Integration (Rule 1405 & NESHAP)

Integrated within advanced CEMS platforms through industry partnerships and leading experts, AROMA delivers real-time, precise measurements without disrupting existing monitoring workflows. 

Key Features:

  • Seamless integration with full CEMS solutions for EtO
  • Continuous, direct sampling to support regulatory reporting 

4 Leak Detection & Fugitive Emissions Monitoring

AROMA enables early detection of leaks and fugitive emissions, helping industries proactively manage air toxics and reduce environmental impact. With real-time, high sensitivity VOC monitoring, facilities can quickly identify leaks, track emission sources, and take corrective action to stay within regulatory limits. 

Key Features:

  • Ultra-sensitive VOC detection for pinpointing even the smallest leaks
  • On-demand, real-time analysis and no need for canister samples or lab delays
  • Automated concentration mapping to visualize leak locations and trends
  • Detect leaks before they lead to violations
  • Regulatory alignment with LDAR (Leak Detection and Repair) programs
  • Mobile and stationary options

5 Stack & Source Testing

Beyond traditional stack testing, AROMA enables precise VOC measurement for emissions characterization, process optimization, and compliance. Its rapid response and high sensitivity provide unmatched data quality across various industrial sources. 

Key Features: 

  • High-sensitivity VOC detection for compliance and process control
  • Real-time data with minimal downtime and high accuracy
  • On-site, mobile deployment for flexible source testing applications
  • Portable and easy to deploy for quick source assessments
  • Supports regulatory reporting and emissions characterization

 

Compliance Across Key Markets

Monitoring with Entanglement Technologies’ AROMA analyzer aligns with air quality regulations in the U.S., Europe, Canada, and other major markets.

  • Examples of key regulations include:
    • United States
      • EPA Hazardous Organic NESHAP (HON rule) – Effective April 9, 2024, the updated HON rule mandates stricter emissions standards for facilities handling HAPs, including benzene, 1,3-butadiene, ethylene dichloride, ethylene oxide, and vinyl chloride. Requires fenceline monitoring and root cause analysis at affected chemical plants. 
      • EPA NESHAP for EtO Commercial Sterilizers – Requires continuous emissions monitoring (CEMS) for ethylene oxide at nearly 90 sterilization facilities nationwide. 
      • South Coast AQMD Rule 1405 – Requires CEMS and fenceline monitoring of ethylene oxide emissions from sterilization facilities and related operations.
      • EPA Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA) – Proposed rule aims to reduce sterilization worker exposure to EtO. Facilities must monitor EtO in both processing and non-processing areas and trigger alarms when there is an exceedance.
    • European Union
      • Industrial Emissions Directive (IED) & Best Available Techniques (BAT) Conclusions – Establishes stricter VOC emissions monitoring requirements for industrial sites. 
      • Air Quality Standards (2008/50/EC)- Enforces limits on benzene and other toxic air pollutants. 
    • Canada
      • Canadian Ambient Air Quality Standards (CAAQS)- Sets national air quality objectives for benzene and other hazardous VOCs.
      • Environmental Emergency Regulations- Requires risk assessments and monitoring for facilities handling toxic substances.

Navigating Global Compliance Challenges

With increasing complexity on air toxics compliance, industries need fast, accurate, and cost-effective solutions. AROMA provides the data and insights necessary to meet evolving compliance needs worldwide while helping facilities reduce cost, minimize environmental impact, and safeguard workers. 

For more information or to discuss compliance strategies, contact us.

 